Viscometer^ BS/IP/RF U-Tube Reverse Flow Viscometer measures kinematic viscosity of opaque Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 7 mL. Minimum bath depth is 11 in. Size 9. Approximate constant is 30 cSt/s. Viscosity range is 6000 - 30000 cSt.
|
Flow Viscometer^ BS/IP/RF U-Tube Reverse Flow Viscometer measures kinematic viscosity of opaque Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 7 ml, Minimum bath depth: 11 in, Size 1, Approximate constant is 0.003 cSt/s. Viscosity range is 0.6 - 3 cSt.
|
Flow Viscometer^ BS/IP/RF U-Tube Reverse Flow Viscometer measures kinematic viscosity of opaque Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 7 ml, Minimum bath depth: 11 in, Size 2, Approximate constant is 0.01 cSt/s. Viscosity range is 2 - 10 cSt.
|
Flow Viscometer^ BS/IP/RF U-Tube Reverse Flow Viscometer measures kinematic viscosity of opaque Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 7 ml, Minimum bath depth: 11 in, Size 3, Approximate constant is 0.03 cSt/s. Viscosity range is 6 - 30 cSt.
|
Viscometer^ BS/IP/RF U-Tube Reverse Flow Viscometer measures kinematic viscosity of opaque Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 7 mL. Minimum bath depth is 11 in. Size 4. Approximate constant is 0.1 cSt/s. Viscosity range is 20 - 100 cSt.
|
Viscometer^ BS/IP/RF U-Tube Reverse Flow Viscometer measures kinematic viscosity of opaque Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 7 mL. Minimum bath depth is 11 in. Size 5. Approximate constant is 0.3 cSt/s. Viscosity range is 60 - 300 cSt.
|
Viscometer^ BS/IP/RF U-Tube Reverse Flow Viscometer measures kinematic viscosity of opaque Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 7 mL. Minimum bath depth is 11 in. Size 6. Approximate constant is 1 cSt/s. Viscosity range is 200 - 1000 cSt.
|
Viscometer^ BS/IP/RF U-Tube Reverse Flow Viscometer measures kinematic viscosity of opaque Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 7 mL. Minimum bath depth is 11 in. Size 7. Approximate constant is 3 cSt/s. Viscosity range is 600 - 3000 cSt.
|
Viscometer^ BS/IP/RF U-Tube Reverse Flow Viscometer measures kinematic viscosity of opaque Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 7 mL. Minimum bath depth is 11 in. Size 8. Approximate constant is 10 cSt/s. Viscosity range is 2000 - 10000 cSt.
|
Viscometer^ BS/IP/RF U-Tube Reverse Flow Viscometer measures kinematic viscosity of opaque Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 7 mL. Minimum bath depth is 11 in. Size 10. Approximate constant is 100 cSt/s. Viscosity range is 20000 - 100000 cSt.
|
Viscometer^ BS/IP/RF U-Tube Reverse Flow Viscometer measures kinematic viscosity of opaque Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 7 mL. Minimum bath depth is 11 in. Size 11. Approximate constant is 300 cSt/s. Viscosity range is 60000 - 300000 cSt.
|